SE-98

Dynamic Stress-strain Testing and Analysis System - SE-98

The SE-98 Dynamic Stress-Strain Testing and Analysis System is a high-performance testing platform designed for structural integrity evaluation of large-scale components and assemblies. Its modular architecture and synchronized acquisition technology provide comprehensive solutions for strength, stiffness, and fatigue life assessment across various industries.

  • Specially designed for the testing of stress and strain, and the physical quantities of force, pressure, displacement, velocity, acceleration can be accurately tested by cooperating with various bridge sensors, and the signal of voltage can also be accurately measured.

  • Suitable for cabinet installation and can be used to build a centralized test system to support the online synchronous loading of various load testing machines for the fatigue test of large structures

  • The maximum sampling rate is 5kHz/channel for simultaneous sampling of all channels

  • Built-in standard resistance, software-settable of full-bridge, half-bridge and three-wire quarter bridge

  • The function of intelligent wire identification is supported to facilitate the editing and setting of measurement point information in large system

  • Support synchronous automatic measurement and correction of wire resistance of all channels

  • The self-checking function of in-situ channels of strain-stress is supported to obtain the current state of the channel quickly

  • The multi-channel signal can be recorded for a long time, in real time and without interruption by using computer's hard disk with large capacity

SE 98
Name Detail
Number of Input Channel8 channels per card, 8/16 card slots per chassis
Full-scale Voltage Value±0.05V, ±0.5V, ±5.0V, ±10.0V
Min. Resolution5μV
Strain Measurement
   Full-scale Strain Value±50000με
   Min. Resolution0.5με
   Indication errorSE-98-S DAQ Card: <0.5%±3με
SE-98-H DAQ Card: <0.3%±3με
   Nonlinearity0.1% of F.S.
   Noise≤1μεRMS
   Zero Drift≤3με/2h
   Self-Balancing Range±20000με (±2% of strain gauge resistance)
   Strain Gauge Sensitivity Coefficient1.0 ~ 3.0 (Auto. calibrating)
Bridge Excitation
   Bridge ConfigurationFull, half, three-wire quarter bridge
   Bridge Completion Resistors120Ω, 350Ω (Three-wire quarter bridge)
60Ω ~ 20000Ω (Half bridge / Full bridge)
   Bridge Voltage2V, 5V, 10V DC
   Accuracy<0.1%
   Stability<0.05/h
   Max. Output current20mA/CH
LPF
   Transfer Characteristic6th order Butterworth and Chebyshev filter
   Cut-off Frequency10Hz, 30Hz, 100Hz, 300Hz, PASS
CommunicationEthernet
A/D Converter24 bits
Freq. ResponseSE-98-S DAQ Card: DC ~ 35Hz (+0.5dB to -3dB), 30Hz flat (0.1dB)
SE-98-H DAQ Card: DC ~ 1kHz (+0.5dB to -3dB), 250Hz flat (0.1dB)
Single Chassis(16cards): 1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 200Hz, 500Hz, 1kHz per channel
SE-98-S DAQ Card
Multiple-Chassis(with NTP): 1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 200Hz, 500Hz per channel
Multiple-Chassis(with Sync. clock cable): 1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 200Hz, 500Hz, 1kHz per channel
Single Chassis(16cards): 1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 200Hz, 500Hz, 1kHz, 2kHz, 5kHz per channel
Sampling RateSE-98-H DAQ Card
Multiple-Chassis(with NTP): 1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 200Hz, 500Hz per channel
Multiple-Chassis(with Sync. clock cable): 1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 200Hz, 500Hz, 1kHz 2kHz, 5kHz per channel
SE-98-S DAQ Card and SE-98-H DAQ Card
Single Chassis(16cards): 1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 200Hz, 500Hz, 1kHz per channel
Multiple-Chassis(with NTP): 1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 200Hz, 500Hz per channel
Multiple-Chassis(with Sync. clock cable): 1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 200Hz, 500Hz, 1kHz per channel
Anti-aliasing Filter
   Cut-off Frequency1/2.56 of sampling rate
   Stop-band Attenuation>-100dB/Oct.
   Flatness<0.1dB (Within analysis frequency range)
SynchronizationNTP (sampling rate below 500Hz)
Synchronous Clock Cable (sampling rate above 5kHz)
Power Supply220V AC / 10 ~ 30V DC, 160W (64 channels) / 300W (128 channels)
Dimensions Semi-19” Chassis: 237×133×337mm
19” Chassis: 482×133×379mm
Weight Semi-19” Chassis (64 channels): Approx. 5.5kg
19” Chassis (128 channels): Approx. 12kg
Environmental Conditions
   Operating Temperature0°C to 40°C
   Operating Humidity20 ~ 90%RH@40°C
   Storage Temperature-40°C to 60°C
   Storage Humidity90%RH24h@50°C
   Vibration Frequency cycle range: 5Hz ~ 55Hz ~ 5Hz
Drive amplitude (peak): 0.19 mm
Sweep frequency: ≤1Oct./min
Duration of resonant: 10 min
Vibration direction: x, y, z
SE-98 figure 1

Figure 1  Single System Block Diagram

multi system block diagram

Figure 2 Multiple System Block Diagram

DE-BSP Basic Platform Software

Key Features & Capabilities

  • Cross-Platform Compatibility

    ✓Supports Windows XP/7/8/10 operating systems

  • Comprehensive Testing Workflow

    ✓Parameter Configuration: Intuitive setup for test

    conditions

    ✓Real-Time Control: Immediate system response during

    acquisition

    ✓Dual-Mode Analysis:

    ✓Detailed post-processing of recorded data

  • Advanced Data Interaction

    ✓Waveform browsing with smart cursor measurements

    ✓Dynamic scaling/curve adjustment tools

    ✓Project-based data management system

  • Automated Reporting

    ✓Customizable report templates

    ✓Export in multiple formats (PDF/Excel/Word)

  • Reliable Data Integrity

    ✓Uninterrupted recording for long-duration tests

    ✓Built-in data validation algorithms

    Engineering Applications

    • Structural fatigue testing

    • Material property characterization

    • Environmental stress screening

    • Academic research experiments

Accessories
Accessories
DE-92U Semi-19" 3U Chassis
8 Card Slots
Including control card, 100 Megabit Network communication Interface
100 ~ 240VAC / 12VDC power supply
DAQ card
DE-93U 19" 3U Chassis
16 card slots
Including control card, 100 Megabit Network communication Interface
100 ~ 240VAC / 12VDC power supply
chassis
SE-98-H DAQ Card
8 channels,
Simultaneous sampling of all channels,
Maximum continuous sampling rate of 5kHz per channel,
Programmed to set the full bridge, half bridge, 1/4 bridge (three-wire system) bridge state,
Individual 24-bit A/D converter per channel,
Support intelligent wire identification,
Automatic wire resistance correction.
chassis
SE-98-S DAQ Card
8 channels,
Simultaneous sampling of all channels,
Maximum continuous sampling rate of 1kHz per channel,
Programmed to set the full bridge, half bridge, 1/4 bridge (three-wire system) bridge state,
Individual 24-bit A/D converter per channel,
Support intelligent wire identification,
Automatic wire resistance correction.
loop conditioner
SE-98-T Thermocouple DAQ Card(Option)
Channel No.: 8 channels of thermocouples + 8 channels of PT100 (built-in card);
Measurement accuracy (calibrated at a temperature of 23℃ ± 5℃):
(1) -20℃ ~ +200℃, < ±0.55℃ (T scale);
(2) +200℃ ~ +800℃, < ±0.9℃ (E scale);
(3) Above +800℃, < ±1.1℃ (K scale);
Suitable for temperature measurement using various thermocouple sensors such as T, E, K, S, J, B, R, N, etc.
Each channel can independently select the type of thermocouple;
Each thermocouple channel is equipped with a thermocouple open-circuit display discrimination function, which can automatically zero and perform temperature drift compensation;
Frequency response range: DC ~ 1kHz (+0.5dB ~ -3dB), 250Hz flat (0.1dB);
A/D converter: 24-bit Σ-Δ A/D converter;
SE-98-R RTD DAQ Card(Option)
Channel No.: 8 channels per card;
Four-wire PT10/Pt100/Pt1000 measurement accuracy (calibrated at 23℃ ± 5℃ ambient temperature):
(1) -20℃ to +100℃ (100Ω), < ±0.3℃;
(2) +100℃ to +250℃, < ±0.5℃;
Measurement range: -20℃ to +250℃;
Platinum resistance excitation current: 500µA;
Frequency response range: DC to 1kHz (+0.5dB to -3dB), 250Hz flat (0.1dB);
A/D converter: 24-bit Σ-Δ A/D converter;
SE-98-V Voltage DAQ Card(Option)
Channel No.: 8 channels per card;
Measurement accuracy (standard environmental temperature of 23℃ ± 5℃): < ±0.05% F.S (for ranges above 10mV);
Voltage measurement range: ±10000mV, ±5000mV, ±1000mV, ±200mV, ±100mV, ±10mV, with step-by-step switching;
Input impedance: >10MΩ;
Maximum common-mode voltage: >10V;
Common-mode rejection ratio: > 95dB;
Channel crosstalk: >90dB;
Frequency response range: DC to 1kHz (+0.5dB to -3dB), flat at 250Hz (0.1dB);
SE-98-C Current DAQ Card(Option)
Measurement accuracy (standard environmental temperature of 23℃ ± 5℃): < ±0.05% F.S;
Current measurement range: 0 - 20mA;
Power supply: 24V / 60mA / CH;
Input impedance: > 10MΩ;
Maximum common mode voltage: > 10V;
Common mode rejection ratio: > 95dB;
Channel crosstalk: > 90dB;
Frequency response range: DC - 1kHz (+0.5dB - -3dB), 250Hz flat (0.1dB);
A/D converter: 24-bit Σ-Δ A/D c
SE-98-D DI/o DAQ Card(Option)
Channel No.: 8 channels of DI and 8 channels of DO per card;
The DI contact types support two options: wet contacts and dry contacts;
DO includes 4 power output channels and 4 TTL output channels;
The maximum output voltage of the power output channels is 24V/1A.
DT5611A Synchronization Box(Option)
8 inputs.
Built-in synchronization clock distributor.
Support multiple clock box cascade connection.
19" 1.5U chassis.
sync box
C-4 Cable
4 channel.
Default 5m bare cable or 1.5 m cable with bridge box.
C-4 cable
Power Cable power cable
Gigabit Network Cable
5m
gigabit cable
BNC Patch Cord
One a DB-26 connector and other is a BNC female connector, 0.1m
patch cord
BNC Cable(Option) bnc cable
IEPE Signal Input Cable(Option) iepe cable
L5 Cable(Option) L5 cable
Tachometer/Counter Signal Cable(Option) tachometer cable
Digital I/O Signal Input Cable(Option) i/o input cable
Synchronous Clock Cable(Option) sync clock cable
Synchronous Clock Cascade Cable(Option) sync clock cascade cable
Gigabit Switch(Option) gigabit switch
Copper Core Nylon Cable Cap (with Copper Core) Copper nylon cable case
Packing Case Case
Fuse fuse
Software CD CD