Dynamic Stress-strain Testing and Analysis System - SE-98
The SE-98 Dynamic Stress-Strain Testing and Analysis System is a high-performance testing platform designed for structural integrity evaluation of large-scale components and assemblies. Its modular architecture and synchronized acquisition technology provide comprehensive solutions for strength, stiffness, and fatigue life assessment across various industries.
Specially designed for the testing of stress and strain, and the physical quantities of force, pressure, displacement, velocity, acceleration can be accurately tested by cooperating with various bridge sensors, and the signal of voltage can also be accurately measured.
Suitable for cabinet installation and can be used to build a centralized test system to support the online synchronous loading of various load testing machines for the fatigue test of large structures
The maximum sampling rate is 5kHz/channel for simultaneous sampling of all channels
Built-in standard resistance, software-settable of full-bridge, half-bridge and three-wire quarter bridge
The function of intelligent wire identification is supported to facilitate the editing and setting of measurement point information in large system
Support synchronous automatic measurement and correction of wire resistance of all channels
The self-checking function of in-situ channels of strain-stress is supported to obtain the current state of the channel quickly
The multi-channel signal can be recorded for a long time, in real time and without interruption by using computer's hard disk with large capacity
Name | Detail |
---|---|
Number of Input Channel | 8 channels per card, 8/16 card slots per chassis |
Full-scale Voltage Value | ±0.05V, ±0.5V, ±5.0V, ±10.0V |
Min. Resolution | 5μV |
Strain Measurement | |
Full-scale Strain Value | ±50000με |
Min. Resolution | 0.5με |
Indication error | SE-98-S DAQ Card: <0.5%±3με SE-98-H DAQ Card: <0.3%±3με |
Nonlinearity | 0.1% of F.S. |
Noise | ≤1μεRMS |
Zero Drift | ≤3με/2h |
Self-Balancing Range | ±20000με (±2% of strain gauge resistance) |
Strain Gauge Sensitivity Coefficient | 1.0 ~ 3.0 (Auto. calibrating) |
Bridge Excitation | |
Bridge Configuration | Full, half, three-wire quarter bridge |
Bridge Completion Resistors | 120Ω, 350Ω (Three-wire quarter bridge) 60Ω ~ 20000Ω (Half bridge / Full bridge) |
Bridge Voltage | 2V, 5V, 10V DC |
Accuracy | <0.1% |
Stability | <0.05/h |
Max. Output current | 20mA/CH |
LPF | |
Transfer Characteristic | 6th order Butterworth and Chebyshev filter |
Cut-off Frequency | 10Hz, 30Hz, 100Hz, 300Hz, PASS |
Communication | Ethernet |
A/D Converter | 24 bits |
Freq. Response | SE-98-S DAQ Card: DC ~ 35Hz (+0.5dB to -3dB), 30Hz flat (0.1dB)
SE-98-H DAQ Card: DC ~ 1kHz (+0.5dB to -3dB), 250Hz flat (0.1dB) Single Chassis(16cards): 1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 200Hz, 500Hz, 1kHz per channel SE-98-S DAQ Card Multiple-Chassis(with NTP): 1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 200Hz, 500Hz per channel Multiple-Chassis(with Sync. clock cable): 1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 200Hz, 500Hz, 1kHz per channel Single Chassis(16cards): 1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 200Hz, 500Hz, 1kHz, 2kHz, 5kHz per channel |
Sampling Rate | SE-98-H DAQ Card
Multiple-Chassis(with NTP): 1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 200Hz, 500Hz per channel Multiple-Chassis(with Sync. clock cable): 1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 200Hz, 500Hz, 1kHz 2kHz, 5kHz per channel SE-98-S DAQ Card and SE-98-H DAQ Card Single Chassis(16cards): 1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 200Hz, 500Hz, 1kHz per channel Multiple-Chassis(with NTP): 1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 200Hz, 500Hz per channel Multiple-Chassis(with Sync. clock cable): 1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 200Hz, 500Hz, 1kHz per channel |
Anti-aliasing Filter | |
Cut-off Frequency | 1/2.56 of sampling rate |
Stop-band Attenuation | >-100dB/Oct. |
Flatness | <0.1dB (Within analysis frequency range) |
Synchronization | NTP (sampling rate below 500Hz)
Synchronous Clock Cable (sampling rate above 5kHz) |
Power Supply | 220V AC / 10 ~ 30V DC, 160W (64 channels) / 300W (128 channels) |
Dimensions |
Semi-19” Chassis: 237×133×337mm 19” Chassis: 482×133×379mm |
Weight |
Semi-19” Chassis (64 channels): Approx. 5.5kg 19” Chassis (128 channels): Approx. 12kg |
Environmental Conditions | |
Operating Temperature | 0°C to 40°C |
Operating Humidity | 20 ~ 90%RH@40°C |
Storage Temperature | -40°C to 60°C |
Storage Humidity | 90%RH24h@50°C |
Vibration |
Frequency cycle range: 5Hz ~ 55Hz ~ 5Hz Drive amplitude (peak): 0.19 mm Sweep frequency: ≤1Oct./min Duration of resonant: 10 min Vibration direction: x, y, z |
Figure 1 Single System Block Diagram
Figure 2 Multiple System Block Diagram
DE-BSP Basic Platform Software
Key Features & Capabilities
Cross-Platform Compatibility
✓Supports Windows XP/7/8/10 operating systems
Comprehensive Testing Workflow
✓Parameter Configuration: Intuitive setup for test
conditions
✓Real-Time Control: Immediate system response during
acquisition
✓Dual-Mode Analysis:
✓Detailed post-processing of recorded data
Advanced Data Interaction
✓Waveform browsing with smart cursor measurements
✓Dynamic scaling/curve adjustment tools
✓Project-based data management system
Automated Reporting
✓Customizable report templates
✓Export in multiple formats (PDF/Excel/Word)
Reliable Data Integrity
✓Uninterrupted recording for long-duration tests
✓Built-in data validation algorithms
Engineering Applications
• Structural fatigue testing
• Material property characterization
• Environmental stress screening
• Academic research experiments
Accessories | |
---|---|
DE-92U Semi-19" 3U Chassis
8 Card Slots Including control card, 100 Megabit Network communication Interface 100 ~ 240VAC / 12VDC power supply |
![]() |
DE-93U 19" 3U Chassis
16 card slots Including control card, 100 Megabit Network communication Interface 100 ~ 240VAC / 12VDC power supply |
![]() |
SE-98-H DAQ Card
8 channels, Simultaneous sampling of all channels, Maximum continuous sampling rate of 5kHz per channel, Programmed to set the full bridge, half bridge, 1/4 bridge (three-wire system) bridge state, Individual 24-bit A/D converter per channel, Support intelligent wire identification, Automatic wire resistance correction. |
![]() |
SE-98-S DAQ Card
8 channels, Simultaneous sampling of all channels, Maximum continuous sampling rate of 1kHz per channel, Programmed to set the full bridge, half bridge, 1/4 bridge (three-wire system) bridge state, Individual 24-bit A/D converter per channel, Support intelligent wire identification, Automatic wire resistance correction. |
![]() |
SE-98-T Thermocouple DAQ Card(Option)
Channel No.: 8 channels of thermocouples + 8 channels of PT100 (built-in card); Measurement accuracy (calibrated at a temperature of 23℃ ± 5℃): (1) -20℃ ~ +200℃, < ±0.55℃ (T scale); (2) +200℃ ~ +800℃, < ±0.9℃ (E scale); (3) Above +800℃, < ±1.1℃ (K scale); Suitable for temperature measurement using various thermocouple sensors such as T, E, K, S, J, B, R, N, etc. Each channel can independently select the type of thermocouple; Each thermocouple channel is equipped with a thermocouple open-circuit display discrimination function, which can automatically zero and perform temperature drift compensation; Frequency response range: DC ~ 1kHz (+0.5dB ~ -3dB), 250Hz flat (0.1dB); A/D converter: 24-bit Σ-Δ A/D converter; |
|
SE-98-R RTD DAQ Card(Option)
Channel No.: 8 channels per card; Four-wire PT10/Pt100/Pt1000 measurement accuracy (calibrated at 23℃ ± 5℃ ambient temperature): (1) -20℃ to +100℃ (100Ω), < ±0.3℃; (2) +100℃ to +250℃, < ±0.5℃; Measurement range: -20℃ to +250℃; Platinum resistance excitation current: 500µA; Frequency response range: DC to 1kHz (+0.5dB to -3dB), 250Hz flat (0.1dB); A/D converter: 24-bit Σ-Δ A/D converter; |
|
SE-98-V Voltage DAQ Card(Option)
Channel No.: 8 channels per card; Measurement accuracy (standard environmental temperature of 23℃ ± 5℃): < ±0.05% F.S (for ranges above 10mV); Voltage measurement range: ±10000mV, ±5000mV, ±1000mV, ±200mV, ±100mV, ±10mV, with step-by-step switching; Input impedance: >10MΩ; Maximum common-mode voltage: >10V; Common-mode rejection ratio: > 95dB; Channel crosstalk: >90dB; Frequency response range: DC to 1kHz (+0.5dB to -3dB), flat at 250Hz (0.1dB); |
|
SE-98-C Current DAQ Card(Option)
Measurement accuracy (standard environmental temperature of 23℃ ± 5℃): < ±0.05% F.S; Current measurement range: 0 - 20mA; Power supply: 24V / 60mA / CH; Input impedance: > 10MΩ; Maximum common mode voltage: > 10V; Common mode rejection ratio: > 95dB; Channel crosstalk: > 90dB; Frequency response range: DC - 1kHz (+0.5dB - -3dB), 250Hz flat (0.1dB); A/D converter: 24-bit Σ-Δ A/D c |
|
SE-98-D DI/o DAQ Card(Option)
Channel No.: 8 channels of DI and 8 channels of DO per card; The DI contact types support two options: wet contacts and dry contacts; DO includes 4 power output channels and 4 TTL output channels; The maximum output voltage of the power output channels is 24V/1A. |
|
DT5611A Synchronization Box(Option)
8 inputs. Built-in synchronization clock distributor. Support multiple clock box cascade connection. 19" 1.5U chassis. |
![]() |
C-4 Cable
4 channel. Default 5m bare cable or 1.5 m cable with bridge box. |
![]() |
Power Cable | ![]() |
Gigabit Network Cable
5m |
![]() |
BNC Patch Cord
One a DB-26 connector and other is a BNC female connector, 0.1m |
![]() |
BNC Cable(Option) | ![]() |
IEPE Signal Input Cable(Option) | ![]() |
L5 Cable(Option) | ![]() |
Tachometer/Counter Signal Cable(Option) | ![]() |
Digital I/O Signal Input Cable(Option) | ![]() |
Synchronous Clock Cable(Option) | ![]() |
Synchronous Clock Cascade Cable(Option) | ![]() |
Gigabit Switch(Option) | ![]() |
Copper Core Nylon Cable Cap (with Copper Core) | ![]() |
Packing Case | ![]() |
Fuse | ![]() |