Static Strain Test and Analysis System - SE-86 Static Strain Test and Analysis System - SE-86

The SE-86 Static Strain Test and Analysis System, a compact and intelligent data acquisition system with channel self-checking function, can be used to build a comprehensive test system with tens of thousands of channels, suitable for the measurement of various signals, such as stress, strain, voltage and displacement, easy to use, suitable for indoor and outdoor measurement and test.

Quantity:
Share this:
  • Product Description
  • Specifications
  • System Configurations
  • Software
  • Modules/Accessories

 Modular design, used for distributed measurement or the construction of thousands of channel test system

 Advanced isolation and reasonable grounding technology are used to realize strong anti-interference ability

 Software-settable of full-bridge, half-bridge, public compensation quarter bridge and three-wire quarter bridge

 Support the function of auto measurement and correction of wire resistanceintelligent wire identification and self 

    check of bridge configuration


Number of Input Channel16 channels per DAQ unit, 8 DAQ unit per controller
Full-scale Voltage Value±0.02V, ±5.0V
Voltage Indication Error≤0.5%
Strain Measurement
     Input Strain Range±20000με
     Resolution1με
     Indication Error≤0.5%±3με
     Zero Drift≤3με/4h
     Self-Balancing Range±20000με
     Strain Gauge Sensitivity Coefficient1.0~3.0 (Auto. calibrating)
Bridge Excitation
     Bridge ConfigurationFull, half, three-wire quarter bridge, public compensation quarter bridge
     Bridge Completion Resistors120Ω/350Ω (Three-wire quarter bridge)
60Ω~20000Ω (Public compensation quarter bridge, Half bridge, Full bridge)
     Bridge Voltage2V (Within 0.1% and 0.05%/h)
     Max. Output Current200mA@4 channels
Auto-correcting Range of Wire Resistance0.0 ~ 100Ω
CommunicationRS485 between DAQ unit and controller
Ethernet between controller and computer
Communication Distance (RS485)
     8 acquisition units in control15m between the DAQ units
     4 acquisition units in control30m between the DAQ units
     3 acquisition units in control50m between the DAQ units
A/D Converter24-bit Σ-Δ
Sampling Rate2Hz per channel
Power Supply
     Power/Controller110 ~ 240VAC / 10 ~ 36VDC, 120W
     DAQ UnitDirectly powered by power/controller, 12W
Dimensions
     Power/Controller230mm(L)×153mm(W)×47mm(H)
     DAQ Unit164mm(L)×153mm(W)×47mm(H)
Weight 
     Power/ControllerApprox. 1.35kg
     DAQ UnitApprox. 0.85kg
Environmental Conditions
     Operating Temperature- 10°C to 50°C
     Operating Humidity20 ~ 90%RH@40°C
     Storage Temperature- 40°C to 60°C
     Storage Humidity90%RH24h@50°C
     Vibration
Frequency cycle range: 5Hz ~ 55Hz ~ 5Hz
Drive amplitude (peak): 0.19mm
Sweep frequency: ≤1Oct./min
Duration of resonant: 10min
Vibration direction: x, y, z

Figure 1  Block Diagram of Single Acquisition Unit 


Figure 2  Block Diagram of Multiple Acquisition Units


Figure 3  Block Diagram of Multiple Systems in parallel



DE-BPS Basic Platform Software

  • Running on XP/Win7/Win8/Win10 operating system

  • Parameters setting, Function control, Real-time/post-acquisition analysis, data browsing, cursor readouts, scaling curve, data management and simple processing, report generation, long-term continuous data recording, etc.




 SE-86 Power/Controller
  • Up to 8 data acquisition units (128 measuring channels) can be controlled simultaneously

  • Ethernet communication between computer and power/controller

  • CAN bus is adopted to connect 8 collectors, and the distance between the collectors is not more  than 5 meters

  • RS485 bus is adopted to connect 8 collectors, and the distance between the collectors is not more than 15 meters

SE-86 DAQ Unit
  • 16 input channels

  • Full-scale Voltage Value: ±0.02V, ±5.0V

  • Input Strain Range: ±20000με

  • Independent 24-bit Σ-Δ A/D converter per channel with sampling rate of 2Hz

  • Support the function of auto measurement and correction of wire resistance, intelligent wire ident-ification and self check of bridge configuration

C-4 Signal Input Cable
  • 5-core shield cable                                                                                            

  • High strength PTFE cable, 4-channel per cable

  • Default 5m bare cable or 1.5 m cable with bridge box


×

Contact Us