The SE-86H High-speed Static Strain Data Acquisition Instrument, with a maximum sampling rate of 100Hz, is widely used in fatigue test and pseudo-dynamic test, which can capture the slow-changing signal of the whole process from the elastic region to the plastic region. In addition to the measurement of stress and strain signals, physical quantities such as voltage, displacement and temperature can also be measured.

Quantity:
Share this:
  • Product Description
  • Specifications
  • System Configurations
  • Software
  • Modules/Accessories

 The acquisition instrument can be built into a distributed measurement system or a large rack test system as required

 RS485 bus is used for data transmission between power/controller and DAQ unit, and network port is used for commu-

    nication between power/controller and computer for real-time sampling, transmission, storage and display

 External DC power supply is supported to facilitate on-site measurement and test

 Software-settable of full-bridge, half-bridge and three-wire quarter bridge, easy to use

 Support the function of auto measurement and correction of wire resistanceintelligent wire identification and self 

    check of bridge configuration

Number of Input Channel16 channels per DAQ unit, Max. 8 DAQ units per controller
Full-scale Voltage Value±0.5V, ±5.0V
Min. Resolution5μV
Voltage Indication Error≤0.5%
Nonlinearity≤0.1%
Strain Measurement
     Full-scale Strain Value±50000με
     Min. Resolution0.5με
     Indication Error≤0.5%±3με
     Indication Stability±0.1%/4h
    Noise≤1μεRMS
     Zero Drift≤3με/4h
     Self-Balancing Range±20000με  (±2% of strain gauge resistance)
     Strain Gauge Sensitivity Coefficient1.0 ~ 3.0 (Auto. calibrating)
Bridge Excitation
     Bridge ConfigurationFull, half, three-wire quarter bridge
     Bridge Completion Resistors120Ω, 350Ω (Three-wire quarter bridge)
60Ω~20000Ω (Half bridge / Full bridge)
     Bridge Voltage2V, 5V, 10V (Within 0.1%)
Auto-correcting Range of Wire Resistance0.0 ~ 100Ω
Anti-aliasing Filter
     Cut-off Frequency1/2.56 of sampling rate
     Stop-band Attenuation >-100dB
A/D Converter24 bits
Sampling Rate1Hz, 2Hz, 5Hz, 10Hz, 20Hz, 50Hz, 100Hz per channel
Communication ModeRS485 between DAQ unit and power/controller
Ethernet between power/controller and computer
Communication Distance (RS485)
     8 acquisition units in control15m between the DAQ units
     4 acquisition units in control30m between the DAQ units
     3 acquisition units in control50m between the DAQ units
Power Supply
     Power/Controller110 ~ 240VAC / 10 ~ 36VDC, 120W
     DAQ unitPowered by power/controller directly or Powered by external 10 ~ 36 DC, 15W 
Dimensions
     Power/Controller230mm(L)×153mm(W)×47mm(H)
     DAQ unit230mm(L)×153mm(W)×47mm(H)
Weight 
     Power/ControllerApprox. 1.35kg
     DAQ unitApprox. 1.25kg 
Environmental Conditions
     Operating Temperature- 10°C to 50°C
     Operating Humidity20 ~ 90%RH@40°C
     Storage Temperature- 40°C to 60°C
     Storage Humidity90%RH24h@50°C
     Vibration
Frequency cycle range: 5Hz ~ 55Hz ~ 5Hz
Drive amplitude (peak): 0.19mm
Sweep frequency: ≤1Oct./min
Duration of resonant: 10min
Vibration direction: x, y, z

 

Figure 1  Block Diagram of Single DAQ Unit



Figure 2  Block Diagram of Multiple Systems in parallel



DE-BPS Basic Platform Software

  • Running on XP/Win7/Win8/Win10 operating system

  • Parameters setting, Function control, Real-time/post-acquisition analysis, data browsing, cursor readouts, scaling curve, data management and simple processing, report generation, long-term continuous data recording, etc.




 ME-86H Power/Controller
  • Up to 8 DAQ units (128 channels) can be controlled simultaneously

  • Ethernet communication between computer and power/controller

  • CAN bus is used to connect 8 DAQ units, and the distance between the DAQ units is not more than 5 meters

  • RS485 bus is used to connect 8 DAQ units, and the distance between the DAQ units is not more than 15 meters

ME-86H DAQ Unit
  • 16 input channels

  • Full-scale Voltage Value: ±0.5V, ±5.0V

  • Full-scale Strain Value: ±50000με

  • Independent 24-bit A/D converter per channel with sampling rate of up to 100Hz

  • Support the function of auto measurement and correction of wire resistance, intelligent wire identification and self check of bridge configuration

C-4 Signal Input Cable
  • 5-core shield cable                                                                                            

  • High strength PTFE cable, 4-channel per cable

  • Default 5m bare cable or 1.5 m cable with bridge box


×